Electrical tools & engineering

Tools for panel building, testing and fault-finding.

Find a wire stripper for control wiring, a meter for tracing a fault, or a clamp for a 4–20 mA loop. The product notes explain what each tool does and where its limits matter.

Browse 88 KNIPEX models and 30 meters, including four specialist mA clamps.

As an Amazon Associate I earn from qualifying purchases. Amazon links are marked. Confirm the exact model, seller, price and availability before ordering.

Tools by job

What are you working on?

Choose a task to browse its tools and buying advice.

Technical knowledge

Engineering guides

Browse all topics
Engineering library

Switchgear engineering by subject

Start with the equipment, the control circuit or the test you need to understand.

Six models to consider

Tools for the panel bench and service kit

These models cover different jobs. Each profile sets out the specification and limitations; the Amazon link opens the product listing.

Advertisement · Amazon affiliate links. As an Amazon Associate I earn from qualifying purchases. The links below open product pages on Amazon.de; confirm the exact model and current offer before ordering.

At the wiring bench

KNIPEX PreciStrip16 12 52 195
Wire stripping

KNIPEX PreciStrip16

Article 12 52 195

For control-panel wiring that ranges from fine signal wire to larger conductors.

The 0.08–16 mm² stripping range covers varied wire sizes. Fine adjustment and a length stop help when preparing the same strip length repeatedly.

Cable insulation and conductor construction still matter. The stripping range does not describe cutting or crimping capacity.

KNIPEX NexStrip 12 72 190
Strip and crimp

KNIPEX NexStrip

Article 12 72 190

A compact option for short wiring runs and ferrule terminations in control cabinets.

Cutting, stripping and square crimping share one tool, reducing tool changes when preparing small ferrules.

It strips up to 10 mm², but crimps single ferrules only up to 4 mm². Twin ferrules have a different limit.

KNIPEX Twistor16 97 53 18
Ferrule crimping

KNIPEX Twistor16

Article 97 53 18

For panel builders who want more choice in how a ferrule enters the crimper.

The die head rotates for front or side access. That can make the approach more convenient when preparing leads.

The ferrule range, twin-ferrule limit and finished crimp profile must suit the terminal specification.

Measurement & fault-finding

Fluke 117
Building circuits

Fluke 117

Digital multimeter

For electricians investigating building circuits within its CAT III 600 V rating.

The LoZ mode helps distinguish induced voltage from a supply that can sustain the test load.

There is no dedicated µA input, temperature function or long-term logger. Non-contact detection does not prove isolation.

Fluke 87V
Motor drives

Fluke 87V

Digital multimeter

For maintenance work on variable-frequency drives and mixed electrical or electronic faults.

A VFD low-pass filter helps with drive measurements; fast peak capture records brief extremes.

The standard 87V is not the IP67 MAX model. Peak capture cannot show the waveform as an oscilloscope does.

Fluke 773
4–20 mA loops

Fluke 773

Process mA clamp

For instrumentation work on transmitters and PLC analogue inputs.

The remote DC jaw measures current without opening the loop. Source and simulate modes help narrow down a fault.

This is a process-current tool. It does not measure AC leakage, resistance or general mains voltage.

Selection notes

Specifications that affect your choice

Ghost voltage

Why does a disconnected wire still show voltage?

A high-impedance meter can display voltage induced by nearby wiring. LoZ applies a lower input impedance, helping distinguish that reading from a supply that can sustain a load.

Fluke 117 and LoZ →
Tool capacity

A 10 mm² stripper may only crimp 4 mm².

On the NexStrip, stripping and crimping have different limits. The single-ferrule range also differs from the twin-ferrule range.

NexStrip working ranges →
mA measurement

AC leakage and DC process current need different clamps.

A milliamp reading alone tells you little about suitability. The clamp must support the current type and range, with enough accuracy for the measurement.

The four mA clamps →

Understanding the circuit

The engineering articles cover switchgear design, protection and testing, with circuit examples and references for the work behind the measurement.

Browse engineering articles →
Reference directories

Equipment and manufacturer references

Find equipment profiles, manufacturer portfolios and resources for engineering work.

Equipment directory

Equipment profiles organised by application, ratings and manufacturer.

Browse equipment →

Manufacturer directory

Manufacturer profiles with links to official portfolios and product families.

Browse manufacturers →

Engineering resources

Checklists, templates, diagrams and calculators for engineering work.

Browse resources →
Industry developments

How switchgear technology is changing

Articles on new insulation systems, digital monitoring and regulation, with links to the companies developing them.

Changes in switchgear technology

F-gas-free insulation, solid dielectrics and digital switchgear, alongside changes in regulation.

Read the technology articles →

Technology providers

Specialists in protection, testing and diagnostics, including monitoring and gas-lifecycle services.

Browse providers →
LearnSwitchgear

Search the engineering library