Tools for panel building, testing and fault-finding.
Find a wire stripper for control wiring, a meter for tracing a fault, or a clamp for a 4–20 mA loop. The product notes explain what each tool does and where its limits matter.
Browse 88 KNIPEX models and 30 meters, including four specialist mA clamps.
As an Amazon Associate I earn from qualifying purchases. Amazon links are marked. Confirm the exact model, seller, price and availability before ordering.
What are you working on?
Choose a task to browse its tools and buying advice.
Wire preparation & termination
Wire stripping
Strippers matched to conductor size and insulation.
Wire strippers →Crimping
Ferrule and connector tools with their crimp profiles and working ranges.
Crimping tools →Cable cutters
Cutters for different cable materials and constructions.
Cable cutters →Installation pliers
Tools that combine gripping, forming and wire preparation.
Installation tools →Measurement & diagnosis
Engineering guides

Protecting medium-voltage feeders
Protection functions and trip logic for incomers, feeders, transformers, motors and capacitor banks.
Read the feeder article →59N vs 64: calculated 3V0 or broken-delta voltage?
How residual voltage is obtained, what the VT connection changes and which commissioning tests matter.
Read the protection article →Wire numbering in switchgear LVCs
Wire-numbering methods, IEC requirements and an EPLAN example using a 110 VDC trip circuit.
Read the wiring article →
G98, G99 and G100: connecting generation in Great Britain
DNO applications, protection and export limitation for solar PV, storage, generators and V2G.
Read the connection article →
DC MCB polarity: why the wiring direction matters
Arc extinction, terminal markings and ABB SB200 DC wiring examples, including voltage-to-earth limits.
Read the DC breaker article →
RTXP 24 test switches: wiring and CT shorting
Contact sequencing, the RK 926 315-AK terminal map and secondary-injection connections.
Read the test-switch article →Switchgear engineering by subject
Start with the equipment, the control circuit or the test you need to understand.
MV Switchgear Fundamentals
Equipment ratings and configurations, insulation and earthing, with internal-arc concepts for selection.
Browse articles →Circuit Breakers & Drives
How vacuum breakers interrupt current, how their mechanisms operate and what timing or coil measurements reveal.
Browse articles →Protection & Control
Relay functions and coordination, CT and VT circuits, trip circuits and IEC 61850 interfaces.
Browse articles →Low-Voltage Compartments
The low-voltage compartment: schematics, terminals and wiring, with EMC and verification requirements.
Browse articles →Testing & FAT
Routine and type tests, FAT methods and the evidence needed to judge acceptance.
Browse articles →Standards & Safety
IEC and IEEE requirements, arc-flash risk and operating safety, alongside environmental regulation.
Browse articles →Tools for the panel bench and service kit
These models cover different jobs. Each profile sets out the specification and limitations; the Amazon link opens the product listing.
Advertisement · Amazon affiliate links. As an Amazon Associate I earn from qualifying purchases. The links below open product pages on Amazon.de; confirm the exact model and current offer before ordering.
At the wiring bench

KNIPEX PreciStrip16
Article 12 52 195
For control-panel wiring that ranges from fine signal wire to larger conductors.
The 0.08–16 mm² stripping range covers varied wire sizes. Fine adjustment and a length stop help when preparing the same strip length repeatedly.
Cable insulation and conductor construction still matter. The stripping range does not describe cutting or crimping capacity.

KNIPEX NexStrip
Article 12 72 190
A compact option for short wiring runs and ferrule terminations in control cabinets.
Cutting, stripping and square crimping share one tool, reducing tool changes when preparing small ferrules.
It strips up to 10 mm², but crimps single ferrules only up to 4 mm². Twin ferrules have a different limit.

KNIPEX Twistor16
Article 97 53 18
For panel builders who want more choice in how a ferrule enters the crimper.
The die head rotates for front or side access. That can make the approach more convenient when preparing leads.
The ferrule range, twin-ferrule limit and finished crimp profile must suit the terminal specification.
Measurement & fault-finding

Fluke 117
Digital multimeter
For electricians investigating building circuits within its CAT III 600 V rating.
The LoZ mode helps distinguish induced voltage from a supply that can sustain the test load.
There is no dedicated µA input, temperature function or long-term logger. Non-contact detection does not prove isolation.

Fluke 87V
Digital multimeter
For maintenance work on variable-frequency drives and mixed electrical or electronic faults.
A VFD low-pass filter helps with drive measurements; fast peak capture records brief extremes.
The standard 87V is not the IP67 MAX model. Peak capture cannot show the waveform as an oscilloscope does.

Fluke 773
Process mA clamp
For instrumentation work on transmitters and PLC analogue inputs.
The remote DC jaw measures current without opening the loop. Source and simulate modes help narrow down a fault.
This is a process-current tool. It does not measure AC leakage, resistance or general mains voltage.
Specifications that affect your choice
Why does a disconnected wire still show voltage?
A high-impedance meter can display voltage induced by nearby wiring. LoZ applies a lower input impedance, helping distinguish that reading from a supply that can sustain a load.
Fluke 117 and LoZ →A 10 mm² stripper may only crimp 4 mm².
On the NexStrip, stripping and crimping have different limits. The single-ferrule range also differs from the twin-ferrule range.
NexStrip working ranges →AC leakage and DC process current need different clamps.
A milliamp reading alone tells you little about suitability. The clamp must support the current type and range, with enough accuracy for the measurement.
The four mA clamps →Understanding the circuit
The engineering articles cover switchgear design, protection and testing, with circuit examples and references for the work behind the measurement.
Equipment and manufacturer references
Find equipment profiles, manufacturer portfolios and resources for engineering work.
Equipment directory
Equipment profiles organised by application, ratings and manufacturer.
Browse equipment →Manufacturer directory
Manufacturer profiles with links to official portfolios and product families.
Browse manufacturers →Engineering resources
Checklists, templates, diagrams and calculators for engineering work.
Browse resources →How switchgear technology is changing
Articles on new insulation systems, digital monitoring and regulation, with links to the companies developing them.
Changes in switchgear technology
F-gas-free insulation, solid dielectrics and digital switchgear, alongside changes in regulation.
Read the technology articles →Technology providers
Specialists in protection, testing and diagnostics, including monitoring and gas-lifecycle services.
Browse providers →